Maretron Tank Monitor System, Number of Tank Types: 16/Number of Tanks per Tank Type: 16, 100 Milliampere Power Consumption - TLM100-01

SKU: TLM100-01

$314.99

Maretron Tank Monitor System, Number of Tank Types: 16/Number of Tanks per Tank Type: 16, 100 Milliampere Power Consumption - TLM100-01

Transmits liquid levels over an NMEA 2000 interface.

Maretron Tank Monitor System, Number of Tank Types: 16/Number of Tanks per Tank Type: 16, 100 Milliampere Power Consumption - TLM100-01

Can be used in tanks up to 40 in deep.

Maretron Tank Monitor System, Number of Tank Types: 16/Number of Tanks per Tank Type: 16, 100 Milliampere Power Consumption - TLM100-01

Accommodates irregularly shaped tanks with 16 point calibration.

Maretron Tank Monitor System, Number of Tank Types: 16/Number of Tanks per Tank Type: 16, 100 Milliampere Power Consumption - TLM100-01

16 programmable tank types including fuel, fresh water, waste water, live well.

Maretron Tank Monitor System, Number of Tank Types: 16/Number of Tanks per Tank Type: 16, 100 Milliampere Power Consumption - TLM100-01

Programmable tank number up to 16 per tank type.

Out of stock

Shipping & Returns

Shipping

Most in-stock products ship within 1-3 business days. Your available shipping method and final shipping cost will be shown at checkout. Qualifying standard-shipping orders of $150 or more ship free, while larger items may require oversized or freight delivery.

For more information, view our Shipping Policy.

Returns

Changed your mind? Most products can be returned within 30 days of delivery as long as they are unused, uninstalled, and in their original condition.

Contact us to start a return, and we’ll guide you through the next steps.

For complete details, view our Returns & Refunds Policy.

Warranty

Available warranty coverage is provided by the manufacturer and varies by brand and product. Modridge assists customers with eligible warranty claims and helps coordinate the review process with the manufacturer.

Contact us before returning, repairing, modifying, or discarding a product that may be defective. Order information, photographs, installation details, and diagnostic information may be required.

For coverage details and claim instructions, review our Warranty Policy.

Prop 65 Warning

WARNING: Cancer and reproductive harm - www.P65Warnings.ca.gov

  • Visa
  • Mastercard
  • Diners Club
  • PayPal
  • American Express
Maretron Tank Monitor System, Number of Tank Types: 16/Number of Tanks per Tank Type: 16, 100 Milliampere Power Consumption - TLM100-01

$314.99

$314.99

Measures Up To 16 Tanks

Capacity

Product Description

Maretron's tank monitor system is used to sense fluid levels of tanks by using ultrasonic technology. Ultrasonic, or sound waves, are transmitted via the tank monitor system mounted at the top of the tank and the flight times of the sound waves to and from the fluid are measured much like a depth sensor. What this means for you is that there are no difficult to handle long probes protruding into the tank, which often foul and/or corrode.

Once the tank monitor system calculates and transmits the fluid level over the NMEA 2000 network, you can observe tank levels anywhere on the vessel where there is an NMEA 2000 compatible display such as Maretron's N2KView vessel monitoring system, or by Maretron's DSM570 / DSM410 color graphics displays. The tank monitor system is capable of sensing fluid levels in tanks up to 40 Inch (1.02 Meter) in depth. It can be used for diesel, fresh water, waste water, black water, and oil tanks.

Unlike most tank senders that only work with rectangular tanks, the tank monitor system can be calibrated for irregular tank shapes so you can know the true fluid level in your tanks.


Additional Details

  • Integrated ultrasonic level sensor.
  • Can be used in tanks up to 40 inch deep.
  • SAE J1810 5-hole, 1-1/2 inch NPT, or 1-1/4 inch BSP mounting.
  • Programmable tank capacity.
  • Limited 2 year warranty.
  • Used to monitor level for diesel tank/ fresh water tank/ waste water tank/ black water tank/ oil tanks up to 40 inch depth.
  • 100 milliampere power consumption.
  • 9 to 16 volt DC operating voltage.
  • -25 to 55 degree celsius fahrenheit operating temperature/ -40 to 70 degree celsius fahrenheit storage temperature.
  • Reverse battery protection/ load dump protection.
  • Approvals: NMEA 2000 approved/ IEC 60945/ FCC certified/ CE certified.
  • With gasket/ packet of petroleum jelly/ user manual.

Specifications

Used For
Monitor Level For Diesel Tank/ Fresh/Waste Water Tank/ Black Water Tank/ Oil Tanks For 40 Inch Depth
Display Type
No Display
Panel Size
Not Applicable
Capacity
Measures Up To 16 Tanks
With Alarm
No
With Monitor
No
With Tank Sensor
Yes
With Connector
Yes
Additional Specification
IP67 Waterproof

Installation & Documents

Recently viewed products

Learn Before You Upgrade

  • Will It Fit Your Vehicle?

    A clear, step-by-step guide to verifying vehicle details, fitment notes, and part numbers before you buy.

    Read the Fitment Guide
  • DIY or Professional Install?

    Know the tools, time, supporting parts, and follow-up work before the installation begins.

    Plan Your Installation
  • Build It Once. Build It Right.

    Learn how to plan compatible upgrades in the right order and avoid paying twice for the same result.

    Plan Your Build
Image alt
Image alt
Image alt